Inicio >  Term: gas-meter adjuster
gas-meter adjuster

A professional who tests ability of gas meters to accurately measure specified volume of gas at maximum and average cubic-feet-per-hour capacity and adjusts meters to correct excessive registration error. Responsibilities include:

  • Connects hoses from prover to meter inlet and outlet and raises prover bell until prover gauge registers zero.
  • Turns valve to allow measured amount of air or gas to pass through meter at specified flow-rate.
  • Closes valve and compares registration on meter gauge.
  • Screws fitting into meter outlet to retard flow of gas and repeats test.
  • Turns setscrews to adjust meter and repeats test until meter registration is within specified limits according to prover and meter gas readings.
  • Analyzes test results to determine cause of persistent registration errors.
  • Segregates meters requiring repair.
  • Records test results and date on meter card.
  • May maintain temperature of oil used as gas seal in prover within specified limits to ensure accurate and uniform test readings.
  • May test ability of flowmeters to accurately measure gas and liquid and be designated flowmeter test and certification technician.